1>. Product Name
Delay Relay Module
2>. Product Number
XY-WJ01
3>. Working Voltage
DC 6V-30V
4>. Control Load Current
10A(Max)
5>. Quiescent Current
15mA
7>. Working temperature
-40~85℃
8>. Operating Humidity
5%-99%RH
9>. Suitable for battery
Storage Battery, Lithium battery
10>. Trigger signal source
High level trigger (3.0V~24V), Low level trigger (0.0V~0.2V), switching control (passive switch)
11>. Reverse Protection
Yes
12>. Physical Dimension
79*44*26mm
P0
Relay will keep ON for time OP after get trigger signal and then relay OFF;The input signal is invalid if get trigger signal again during delay time OP.
P1
Relay will keep ON for time OP after get trigger signal and then relay OFF;Module will restart delay if get trigger signal again during delay time OP.
P2
Relay will keep ON for time OP after get trigger signal and then relay OFF;Module will reset and stop timing if get trigger signal again during delay time OP.
P3
Relay will keep OFF for time CL after get trigger signal and then relay keep ON.
P4
Relay will keep ON for time OP after get trigger signal and then relay keep OFF for time CL and then loops the above action.Module will reset and stop timing and relay will keep initial state if get trigger signal again during loops.The number of cycles (LOP) can be set.Relay will keep OFF if end loop.
P5
Relay will keep OFF for time CL after get trigger signal and then relay keep ON for time OP and then loops the above action.Module will reset and stop timing and relay will keep initial state if get trigger signal again during loops.The number of cycles (LOP) can be set.Relay will keep ON if end loop.
P6
Relay will keep ON for time OP after power on without get trigger signal and then relay keep OFF for time CL and then loops the above action.The number of cycles (LOP) can be set.Relay will keep OFF if end loop.
P7
Relay will keep OFF for time CL after power on without get trigger signal and then relay keep ON for time OP and then loops the above action.The number of cycles (LOP) can be set.Relay will keep ON if end loop.
P8
Signal hold function.Reset delay time and relay keep ON if keep get trigger signal.Relay OFF when the signal disappears after delay time OP.Reset delay time when get trigger signal again during timing.
P9
Signal hold function.Reset delay time and relay keep OFF if keep get trigger signal.Relay ON when the signal disappears after delay time CL.Reset delay time when get trigger signal again during timing
P0~P7 mode
System will start to delay if short press button ‘Pause’ when system does not get trigger signal.Display screen will display ‘OUT’ and flashing and Relay OFF when Pause timing if the system has been timed.
P8~P9 mode
Other buttons cannot be used when ‘Pause’ button as a trigger signal in running interface.
LOP
Number of cycles.Range is 1-9999tims.’----’ means unlimited loop.
Long press
keep press button for more than 3second.
Note
Short press ‘SET ’ is invalid at mode P0,P1,P2,P3,P7,P8.
1>.Auto sleep function
Long press button 'Pause' in the normal running interface(P0~P7) to turn on or off auto sleep function.
L-P
OFF,Turn OFF auto sleep function.
2>.View parameters
In the running interface, short press the SET button to display the current parameter settings of the system, which does not affect the normal operation of the system.
3>.Switch the display parameter
It will switch the display content by short press button 'DOWN' in the P5~P6 mode(Parameter is Run time or number of cycles)